1. Observe the cooling effect
An important way to judge whether the Mold Waterway Water Isolation Sheet is working properly is to observe the cooling effect of the mold. If the water isolation sheet is working properly, the cooling system of the mold should be able to effectively reduce the temperature of the mold so that the mold remains within the appropriate temperature range during the production process. The temperature of different parts of the mold can be measured to determine whether the cooling effect is uniform. If it is found that the temperature of some parts is too high, while the temperature of other parts is normal, there may be a problem with the water isolation sheet, resulting in uneven cooling water flow. For example, in an injection mold, if some areas of the mold are overheated, it may cause quality problems such as deformation and shrinkage of plastic products. At this time, it is necessary to check whether the water isolation sheet is working properly.
2. Check the water circuit pressure
Another way to judge whether the water isolation sheet is working properly is to check the pressure of the mold water circuit. Under normal circumstances, the pressure of the mold water circuit should be kept within a stable range. If the water isolation sheet fails, it may cause abnormal water circuit pressure. A pressure sensor can be used to monitor the pressure change of the water circuit. If the pressure is found to be too high or too low, it may be that the water isolation sheet is blocked, damaged or improperly installed. For example, if the water isolation sheet is blocked, the water flow will be blocked and the pressure will increase; if the water isolation sheet is damaged, the water flow may leak and the pressure may decrease. At this time, the water isolation sheet needs to be checked and replaced in time to ensure the normal operation of the mold.
3. Observe the water flow
You can also judge whether the water isolation sheet is working properly by observing the water flow in the mold waterway. Under normal circumstances, the water flow should be smooth, without blockage and leakage. You can open the waterway valve of the mold and observe the speed and flow of the water flow. If you find that the water flow is slow, intermittent or there is a leak, there may be a problem with the water isolation sheet. For example, if the water isolation sheet is not installed properly, it may cause water leakage and affect the cooling effect; if the water isolation sheet is blocked, the water flow speed will slow down and affect the cooling efficiency. At this time, you need to check the installation and cleanliness of the water isolation sheet and deal with the problem in time.
4. Regular inspection and maintenance
In order to ensure the normal operation of the Mold Waterway Water Isolation Sheet, regular inspection and maintenance are required. You can formulate an inspection plan to regularly check the installation, cleanliness and integrity of the water isolation sheet. If the water isolation sheet is found to be damaged, deformed or blocked, it should be replaced or cleaned in time. At the same time, the water system of the mold can also be cleaned and maintained to ensure that the waterway is unobstructed. In addition, the specifications and models of the water isolation sheet can be adjusted in time according to the use of the mold and production requirements to improve the cooling efficiency and production quality of the mold. In short, by observing the cooling effect, checking the waterway pressure, observing the water flow and regular inspection and maintenance, it is possible to effectively determine whether the Mold Waterway Water Isolation Sheet is working properly and ensure the normal operation and production quality of the mold.